You’ll find ECD’s innovative technologies and advanced analyzer instruments are suitable for a wide range of applications in diverse industries, which have been documented and profiled on major industry web sites, trade publications and technical journals.

 

Water Tech, Turbidity Analyzer TR80, Product Showcase, Aug. 1

The smart TR80 Turbidity Analyzer from Electro-Chemical Devices (ECD), offers a flexible and economical solution to safe drinking water or treated effluent suitable for release or reuse. The new, versatile Triton TR80 Turbidity Analyzer features a nephelometric turbidity sensor designed for use in water and wastewater. The Triton TR80 Analyzer relies on the proven optical method with digital communications for determining turbidity and/or suspended solids. A light beam provided by the LED is directed into the sample where it is scattered by the particles or suspended particles in the water. The amount of scattering depends on the amount of impure material in the water, the wavelength of the light used and the size and composition of the particles or suspended solids.

SOURCE

Fluid Handling Magazine, TR82 Turbidity Analyzer, Sept. 2

Analyser detects and measures turbidity in either clear water or wastewater

With its precision nephelometric turbidity sensor designed for use in either municipal or industrial water and wastewater treatment systems, the next-gen TR82 Turbidity Analyser from Electro-Chemical Devices (ECD) gives engineers a highly accurate solution to ensure their treatment systems are performing at high efficiency and at the lowest cost.

The TR82 Turbidity Analyser with its clear water sensor is designed for use in all phases of drinking water treatment and disinfection.

It is ideal for monitoring ground water sources or surface water storage lakes, basins lagoons or ponds, as well as in the control of clear rinse water and in filter rupture or backwash monitoring systems.

The system’s suspended solids sensor supports both industrial process and municipal water and waste treatment. In food/beverage plants, for example, the analyser is ideal for mixing and blending, and in paper manufacturing it monitors filtrates.

The TR82 also supports municipal wastewater activated and digested sludge treatments before effluent release.

The Triton TR82 uses the optical method for determining the turbidity. A light beam is directed into the sample where it is scattered by suspended particles in the water.
The amount of scattering depends on the amount of material in the water, the wavelength of light, and the size and composition of the suspended particles.

SOURCE

WWD, Triton TR80 Suspended Solids, Aug. 17

The Triton TR80 is a nephelometric turbidity sensor designed for use in water and wastewater. Turbidity, the cloudiness or haziness of a water sample, is caused by particles suspended in the water, typically clay and silt. Since bacteria and viruses can be attached to these particles, turbidity has become a critical indicator of the overall water quality.

The Triton TR80 uses an optical method for determining the turbidity suspended solids, a light beam is directed into the sample where it is scattered by suspended particles in the water. The amount of scattering depends on the amount of material in the water, the wavelength of light used and the size and composition of the suspended particles. The TR80 uses a long lived near infrared LED light source and the 90° scattered light method in accordance with ISO 7027 / EN 27027 to assure accurate turbidity values under standardized and comparable conditions. The 90° scattered light detection method is the most common sensor design for turbidity. This sensor has the advantage of a high sensitivity for turbidity throughout the measurement range and a simple optical configuration with an automated cleaning wiper.

The TR80 sensor can be configured for turbidity and/or Suspended Solids and connects with the ECD T80 Transmitter or the ECD LQ800 Multi-Channel Controller.

SOURCE

Enviro-Tech Online, Plug-n-Play De-Chlorination Analyzer, Jan. 5

Municipal water system and industrial process engineers in search of an analyser that accurately measures near zero levels of chlorine will want to learn more about the plug-n-play, long-life DC80 De-Chlorination Analyser from Electro-Chemical Devices (ECD), which utilises a zero-shift methodology to ensure stable and reliable chlorine measurement prior to effluent discharge.

When measuring near zero amounts of chlorine, conventional amperometric chlorine sensors are unstable, and this leads to inaccurate or inconsistent readings. In comparison, the DC80 De-Chlorination Analyser utilises a “zero-shift” methodology to provide accurate measurement and to protect total chlorine sensors from damage, which occurs when the water samples measured contains near zero or zero levels of chlorine.

In wastewater treatment systems, for example, when monitoring for chlorine just before outfall, there can be no chlorine present and yet measurement is still necessary. When there is no chlorine present then the electrode becomes unstable and finally unresponsive. For this reason, the process of measuring de-chlorination itself becomes problematic. When all of the chlorine is removed then the sensor will provide an inaccurate reading after a few hours and fail after a few days still reporting zero chlorine

Problem solved with the DC80 De-Chlorination Analyser: This next-gen total chlorine analyser uses “zero shifts” technology to monitor near zero amounts of total chlorine. Using this method, some chlorine is actually metered into the sample shifting the zero from a near zero chlorine concentration to a measurable value. The analyser’s offset feature allows the metered value to be subtracted from the measurement.

The presence of chlorine in wastewater treatment effluent, both municipal and industrial, is a potentially harmful contaminant that affects plants and other aquatic life forms.

The DC-80 De-Chlorination Analyser monitors chlorine in drinking water, wastewater, cooling water and other de-chlorination applications from 0.05 – 20 ppm. Its mounted system includes built-in flow control, which eliminates the need for complicated plug-and-play design installs quickly right out of the box.

The DC80 features advanced panel pressure regulators and rotameters. Built-in automatic pH compensation for samples between 4 and 12 pH also eliminates the need for expensive reagents to reduce maintenance and life-cycle costs.

The analyser’s total chlorine sensor is a three electrode amperometric sensor with a gold cathode, silver halide anode and 304 stainless steel counter electrode. The counter electrode provides a stable base potential that minimises drift for superior accuracy. The total chlorine sensor has a micro-porous membrane that allows ions to diffuse in and out of the sensor.

The analyser’s pH sensor provides accurate compensation for samples between 4 and 12 pH, which eliminates the need for a sample conditioning system. The total chlorine sensor graphically displays both the total chlorine and pH levels for easy trend analysis.

The DC80 Analyser is available with either 110-240 VAC or 24 VDC power. The standard configuration features dual measurements, two 4-20 mA outputs and three alarm relays. The user friendly DC80 also is available with an auto clean option that includes a solenoid actuated spray cleaner using either 30 psi process water or air. An easily adjusted timer controls the period and duration of the cleaning cycle.

Source

Sustainability Matters, TC-80 Total Chlorine Analyser, Feb. 1

The plug-n-play TC-80 Total Chlorine Analyser from Electro-Chemical Devices (ECD) offers simplified monitoring for water and treatment processes, easy installation and less maintenance for lower ownership costs. The analyser monitors total chlorine in drinking water, rinse water, cooling water or other fresh water samples from 0.05–20 ppm chlorine as the standard range or 0.005–2.000 ppm with the low-range sensor.

The advanced panel-mount design includes built-in flow control, eliminating the need for complicated pressure regulators and rotameters. Built-in automatic pH compensation also eliminates the need for expensive reagents to reduce maintenance and life-cycle costs.

The device is ready to use after connecting the sample and drain lines, then the power and outputs. The TC-80 is calibrated at the factory before shipment, with calibration accomplished by DPD comparison.

The TCA sensor is a three-electrode amperometric sensor with a gold cathode, silver halide anode and 304 SS counter electrode. The TC-80’s pH sensor provides accurate compensation for samples between pH 4 and pH 12, eliminating the need for expensive sample conditioning systems to control the pH of the solution.

Amperometric chlorine sensors are flow sensitive — the minimum required flow by the sensor is 0.5 ft/s, above this value the output is virtually flow independent. A ‘constant head’ flow controller maintains the optimum flow by the sensor over a wide range of incoming sample flow rates. The minimum flow required is 10 gal/h, and the maximum flow rate is 80 gal/h with the sample going to drain at atmospheric pressure.

The device is available with either 110–240 VAC or 24 VDC power.

Source

0 replies

Leave a Reply

Want to join the discussion?
Feel free to contribute!

Leave a Reply

Your email address will not be published. Required fields are marked *